Chint NXB-63C MCB Breaker 1 pole 6ka

CHINT NL1-63 2 Pole RCCB, 30mA / 300mA, 230/240V AC | VITS Pakistan

Price range: ₨ 6,500 through ₨ 8,500

SKUDescription Ampere Ratings Sensitivity PriceQuantity
NL1-63-01

RCCB, NL1-63, 2P, 30mA

25 Amps 30mA ₨ 6,500
NL1-63-02

RCCB, NL1-63, 2P, 300mA

25 Amps 300mA ₨ 8,500
NL1-63-03

RCCB, NL1-63, 2P, 30mA

40 Amps 30mA ₨ 6,500
NL1-63-04

RCCB, NL1-63, 2P, 300mA

40 Amps 300mA ₨ 8,500
NL1-63-05

RCCB, NL1-63, 2P, 30mA

63 Amps 30mA ₨ 6,500
NL1-63-06

RCCB, NL1-63, 2P, 300mA

63 Amps 300mA ₨ 8,500
Brand:

Product Description

CHINT NL1-63 2 Pole RCCB, 30mA / 300mA, 230/240V AC | VITS Pakistan

Product Overview

The CHINT NL1-63 2 Pole Residual Current Circuit Breaker (RCCB) is designed to detect earth leakage faults and disconnect the electrical supply when residual current exceeds its specified sensitivity. It provides additional protection against electric shock and helps reduce fire risks associated with electrical leakage faults.

Suitable for single-phase electrical distribution systems, this RCCB is available in different rated-current and residual-current sensitivity configurations, including 30mA and 300mA options, depending on the exact model.

Important: The NL1-63 is an RCCB, not an RCBO. It provides residual-current protection only and does not provide built-in overload or short-circuit protection. Install a suitable MCB or fuse for overcurrent protection.

Short Description

SpecificationDetails
BrandCHINT
Series / ModelNL1-63
Product TypeResidual Current Circuit Breaker (RCCB)
Number of Poles2 Pole (2P)
Rated Voltage230/240V AC
Rated Frequency50/60Hz
Rated Current16A, 25A, 32A, 40A, 63A (model dependent)
Residual Current Sensitivity30mA / 300mA options
Detection TypeType AC or Type A, depending on model
StandardIEC/EN 61008-1
MountingDIN Rail
Protection FunctionEarth Leakage / Residual Current Protection
Overload ProtectionNot Built-in
Short-Circuit ProtectionNot Built-in

Technical Specifications

ParameterSpecification
ManufacturerCHINT
Product SeriesNL1-63
Device CategoryRCCB
Poles2P
Rated Operational Voltage (Ue)AC 230/240V
Rated Frequency50/60Hz
Rated Current (In)16A, 25A, 32A, 40A, 63A, depending on configuration
Rated Residual Operating Current (IΔn)30mA / 300mA options
Residual Current TypeAC or A, depending on exact variant
Rated Insulation Voltage (Ui)AC 500V
Rated Impulse Withstand Voltage (Uimp)4kV
Conditional Short-Circuit CurrentDepends on exact model and specified backup protection
MountingDIN Rail
Applicable StandardIEC/EN 61008-1

Model selection note: The 30mA and 300mA sensitivities are separate product configurations, not selectable settings on one device. Rated current, residual-current type, and exact order code must be confirmed before ordering.

Key Features

  • Reliable earth leakage and residual-current fault detection.
  • Two-pole design for single-phase electrical systems.
  • Available with 30mA and 300mA sensitivity options, depending on model.
  • Type AC and Type A configurations available in the NL1 product range.
  • Helps provide additional protection against electric shock.
  • Helps reduce fire risks caused by electrical leakage faults.
  • DIN-rail mounting for electrical distribution boards.
  • Designed for residential, commercial and industrial installations.

Applications

  • Residential distribution boards.
  • Commercial electrical installations.
  • Industrial control and distribution panels.
  • Single-phase electrical circuits.
  • Building electrical protection systems.
  • Electrical installations requiring residual-current protection.

30mA vs 300mA RCCB

SensitivityTypical Application
30mAAdditional protection against electric shock, where required by the installation design and applicable regulations.
300mAInstallation-level leakage protection and reduction of fire risks associated with insulation faults.

Selection guidance: A 300mA RCCB should not be treated as equivalent to 30mA additional protection against electric shock. Select sensitivity according to the installation design, earthing arrangement and applicable electrical regulations.

Type AC vs Type A

TypeDetection Capability
Type ACDetects sinusoidal alternating residual current.
Type ADetects sinusoidal AC and pulsating DC residual current.

Always verify the exact residual-current type printed on the device and stated in its model code before purchase.

Installation & Safety Notes

  • Installation must be carried out by a qualified electrician.
  • Select the rated current according to the circuit and connected load.
  • Install suitable upstream or downstream overcurrent protection as required by the protection coordination design.
  • Verify the correct line and neutral terminal connections using the manufacturer’s wiring diagram.
  • Check the earthing arrangement and compatibility with the installation.
  • Test the RCCB using its test button after installation and according to the manufacturer’s instructions.
  • Do not use an RCCB as a substitute for an MCB or fuse.

Frequently Asked Questions

1. What is the CHINT NL1-63 2 Pole RCCB used for?

It detects residual current caused by earth leakage and disconnects the circuit when the specified operating threshold is reached.

2. Does the NL1-63 provide overload protection?

No. It is an RCCB without built-in overload or short-circuit protection. A suitable MCB or fuse is required.

3. What is the difference between 30mA and 300mA?

30mA is commonly used for additional protection against electric shock. 300mA is generally used for installation-level leakage and fire-risk protection. The correct selection depends on the electrical installation.

4. Is the NL1-63 suitable for single-phase systems?

Yes. The 2P version is designed for compatible single-phase applications.

5. Is the NL1-63 an RCBO?

No. The NL1-63 is an RCCB. An RCBO combines residual-current protection with overload and short-circuit protection.

6. Does CHINT offer Type A and Type AC versions?

Yes. The NL1 product range includes Type A and Type AC configurations. Availability depends on the exact model and order code.

7. What voltage is the 2 Pole NL1-63 designed for?

The CHINT catalogue lists AC 230/240V for the 2P configurations.

Why Choose VITS Pakistan?

VITS – Versatile Industrial Trading & Services supplies electrical protection devices and industrial electrical equipment for residential, commercial and industrial applications.

We support customers with product selection, electrical components, switchgear solutions and industrial supply requirements.

Engineering • Trading • Complete Industrial Solutions

For product pricing, stock availability and technical assistance, contact VITS Pakistan.

Call to Action

Request a Quote

For CHINT NL1-63 2 Pole RCCB pricing, availability and product selection, contact our team.

Button Text: Request a Quote
Button URL: https://www.vits.com.pk/contact-us/
WhatsApp: 03134414901


SEO SETTINGS

Focus Keyphrase:
CHINT NL1-63 2 Pole RCCB

SEO Title:
CHINT NL1-63 2 Pole RCCB 30mA 300mA | VITS Pakistan

URL Slug:
chint-nl1-63-2-pole-rccb

Meta Description:
Buy CHINT NL1-63 2 Pole RCCB with 30mA and 300mA residual current protection options. 230/240V AC single-phase protection. Contact VITS Pakistan for price and availability.

Secondary Keyphrases:

  • CHINT NL1-63 RCCB
  • CHINT 2 Pole RCCB
  • 30mA RCCB
  • 300mA RCCB
  • 230V RCCB
  • 240V RCCB
  • CHINT Earth Leakage Protection
  • Single Phase RCCB
  • CHINT Electrical Protection

Product Tags

CHINT, NL1-63, CHINT NL1-63, NL1-63 2P, 2 Pole RCCB, CHINT RCCB, Residual Current Circuit Breaker, RCCB, Earth Leakage Protection, 30mA RCCB, 300mA RCCB, 230V RCCB, 240V RCCB, Type A RCCB, Type AC RCCB, Single Phase RCCB, Electrical Protection Device, DIN Rail RCCB, Residential RCCB, Industrial RCCB, Electrical Distribution, CHINT Electrical Products, VITS Pakistan

Product Image SEO

Recommended Image Name:
chint-nl1-63-2-pole-rccb-30ma-300ma.webp

Image Alt Text:
CHINT NL1-63 2 Pole RCCB 30mA and 300mA 230/240V AC

Image Title:
CHINT NL1-63 2 Pole Residual Current Circuit Breaker

Image Caption:
CHINT NL1-63 2 Pole RCCB – 30mA / 300mA

Image Description:
CHINT NL1-63 two-pole residual current circuit breaker for single-phase electrical protection, available in different rated-current and residual-current sensitivity configurations.

Recommended Image Format: WebP
Recommended Image Size: 1000 × 1000 pixels
Background: Pure White
Image Style: Clean professional electrical product catalogue photography

Product Specifications

SpecificationDetails
BrandCHINT
ModelNL1-63
Product TypeResidual Current Circuit Breaker (RCCB)
Number of Poles2 Pole (2P)
Rated Voltage230/240V AC
Rated Frequency50/60Hz
Rated Current16A, 25A, 32A, 40A, 63A (model dependent)
Residual Current Sensitivity30mA / 300mA (separate variants)
Residual Current TypeType AC / Type A (model dependent)
StandardIEC/EN 61008-1
MountingDIN Rail
ProtectionEarth Leakage / Residual Current Protection
Overload & Short-Circuit ProtectionNot Built-in; requires separate MCB or fuse

Related Products

CHINT Miniature Circuit Breaker (MCB) 6kA (NXB-63C) MCB Breaker
Price range: ₨ 770 through ₨ 4,400
Price range: ₨ 18,000 through ₨ 36,000

Reviews

There are no reviews yet.

Be the first to review “CHINT NL1-63 2 Pole RCCB, 30mA / 300mA, 230/240V AC | VITS Pakistan”

Your email address will not be published. Required fields are marked *