Chint NXB-63C MCB Breaker 1 pole 6ka

CHINT NXBLE-63 1P+N RCBO, 6A–63A, 6kA Residual Current Circuit Breaker | VITS Pakistan

Price range: ₨ 3,500 through ₨ 4,400

SKUDescription Ampere Ratings PriceQuantity
819975

RCBO, NXBLE-63, 2P, 30 / 300mA

6 Amps ₨ 3,500
819976

RCBO, NXBLE-63, 2P, 30 / 300mA

10 Amps ₨ 3,500
819977

RCBO, NXBLE-63, 2P, 30 / 300mA

16 Amps ₨ 3,500
819978

RCBO, NXBLE-63, 2P, 30 / 300mA

20 Amps ₨ 3,500
819979

RCBO, NXBLE-63, 2P, 30 / 300mA

25 Amps ₨ 4,000
819980

RCBO, NXBLE-63, 2P, 30 / 300mA

32 Amps ₨ 4,000
819981

RCBO, NXBLE-63, 2P, 30 / 300mA

40 Amps ₨ 4,000
819982

RCBO, NXBLE-63, 2P, 30 / 300mA

50 Amps ₨ 4,000
819983

RCBO, NXBLE-63, 2P, 30 / 300mA

63 Amps ₨ 4,400
Brand:

Product Description

CHINT NXBLE-63 1P+N RCBO – Residual Current Circuit Breaker | VITS Pakistan

Product Description

The CHINT NXBLE-63 1P+N Residual Current Circuit Breaker (RCBO) is designed to provide combined electrical protection against earth leakage, overload and short-circuit faults in single-phase AC electrical installations.

By combining the functions of an MCB and residual current protection in one compact device, the NXBLE-63 helps protect electrical circuits, equipment and people against electrical faults.

The 1P+N configuration provides phase protection with a neutral pole. CHINT’s certification documentation identifies the neutral pole in the 1P+N configuration as uninterrupted.

With rated current options from 6A to 63A, multiple residual operating current options and B, C and D tripping characteristics, the NXBLE-63 is suitable for a range of residential, commercial and industrial distribution applications.

Its compact DIN rail mounting design makes it suitable for installation in electrical distribution boards and control panels.

Short Description

SpecificationDetails
BrandCHINT
Product SeriesNXBLE-63
ModelNXBLE-63
Product TypeResidual Current Circuit Breaker (RCBO)
Pole Configuration1P+N
Rated Current6A–63A
Rated Voltage230V AC (catalogue specification; confirm exact variant)
Frequency50/60Hz
Breaking Capacity6kA
Residual Current Options30mA, 50mA, 75mA, 100mA, 300mA
Tripping CurvesB, C, D
Protection FunctionsEarth Leakage, Overload and Short Circuit
MountingDIN Rail
StandardIEC/EN 61009-1

Technical Specifications

Technical ParameterSpecification
ManufacturerCHINT
Product ModelNXBLE-63
Number of Poles1P+N
Rated Current (In)6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Rated Voltage (Ue)230V AC (1P+N catalogue specification)
Rated Frequency50/60Hz
Rated Residual Operating Current (IΔn)0.03A, 0.05A, 0.075A, 0.1A, 0.3A
Residual Current Sensitivity30mA, 50mA, 75mA, 100mA, 300mA
Thermal-Magnetic ReleaseB, C, D
Rated Short-Circuit Breaking Capacity (Icu)6kA
Service Short-Circuit Breaking Capacity (Ics)6kA
Rated Impulse Withstand Voltage (Uimp)4kV (catalogue specification)
Mechanical Life20,000 operations
Electrical Life10,000 operations
Applicable StandardIEC/EN 61009-1
MountingDIN Rail
Pole ConfigurationPhase and Neutral (1P+N)

Protection Functions

1. Earth Leakage Protection

The RCBO detects residual current caused by leakage to earth and disconnects the circuit when the applicable operating threshold is reached.

This function helps reduce the risk of electric shock and electrical fire associated with earth leakage faults.

2. Overload Protection

Thermal protection responds to excessive current flowing through the circuit over time, helping protect cables and connected electrical equipment from overload damage.

3. Short-Circuit Protection

Magnetic protection operates during short-circuit faults and disconnects the circuit to help limit damage to electrical installations.

4. Combined Protection

The NXBLE-63 combines three protection functions in one compact device:

  • Earth leakage protection.
  • Overload protection.
  • Short-circuit protection.

Available Rated Current Options

Current RatingProduct Configuration
6A1P+N RCBO
10A1P+N RCBO
16A1P+N RCBO
20A1P+N RCBO
25A1P+N RCBO
32A1P+N RCBO
40A1P+N RCBO
50A1P+N RCBO
63A1P+N RCBO

Availability of individual ratings is subject to stock confirmation.

Available Tripping Characteristics

CurveGeneral Application
B CurveResistive and low-inrush-current circuits
C CurveGeneral electrical and commercial loads
D CurveLoads with high starting or inrush current

Select the correct curve according to the connected load, cable characteristics and prospective fault current.

Available Residual Current Sensitivity

SensitivityTypical Selection Consideration
30mAAdditional protection against electric shock
50mAApplication-specific residual current protection
75mAApplication-specific residual current protection
100mALeakage protection and installation coordination
300mAHigher-threshold leakage and fire-protection applications

The appropriate sensitivity must be selected according to the electrical installation design and applicable regulations.

Applications

The CHINT NXBLE-63 1P+N RCBO can be used in:

  • Residential distribution boards.
  • Commercial electrical panels.
  • Lighting distribution circuits.
  • Socket outlet circuits.
  • Single-phase electrical installations.
  • Small industrial control panels.
  • Office and retail electrical distribution.
  • Electrical circuits requiring combined earth leakage and overcurrent protection.

Advantages of CHINT NXBLE-63 RCBO

  • Three protection functions in one device.
  • Combined earth leakage, overload and short-circuit protection.
  • 1P+N configuration for single-phase circuits.
  • Current ratings from 6A to 63A.
  • Multiple residual current sensitivity options.
  • B, C and D tripping characteristics.
  • 6kA rated short-circuit breaking capacity.
  • Compact modular construction.
  • DIN rail mounting.
  • Designed in accordance with IEC/EN 61009-1.

Installation and Safety Instructions

  • Installation must be carried out by a qualified electrician.
  • Select the correct rated current according to the connected load and cable capacity.
  • Verify the required residual current sensitivity before installation.
  • Confirm the correct B, C or D tripping characteristic.
  • Follow the manufacturer’s terminal connection diagram.
  • Observe the phase and neutral terminal identification.
  • Ensure proper earthing of the electrical installation.
  • Test the RCBO using its test button according to the manufacturer’s instructions.
  • Isolate the electrical supply before installation or maintenance.

Important: An RCBO does not replace the protective earthing system. Correct earthing, wiring and circuit coordination are essential for safe operation.

Frequently Asked Questions

Q1. What is CHINT NXBLE-63 RCBO?

The CHINT NXBLE-63 is a residual current circuit breaker with integrated overload and short-circuit protection.

Q2. What does 1P+N mean?

1P+N means one protected phase pole and one neutral pole. CHINT’s certification documentation identifies the neutral pole as uninterrupted.

Q3. What protection does the NXBLE-63 provide?

It provides earth leakage, overload and short-circuit protection.

Q4. What current ratings are available?

The product series includes 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A and 63A ratings.

Q5. What is the breaking capacity?

CHINT’s product documentation specifies a 6kA short-circuit breaking capacity.

Q6. What residual current sensitivities are available?

The documented series options include 30mA, 50mA, 75mA, 100mA and 300mA.

Q7. What is the difference between an MCB and an RCBO?

An MCB provides overload and short-circuit protection, whereas an RCBO combines these functions with residual current (earth leakage) protection.

Q8. Can an NXBLE-63 RCBO be used in a single-phase distribution board?

Yes. The 1P+N configuration is intended for suitable single-phase AC applications.

Q9. Does the RCBO protect against electric shock?

Its residual current protection provides additional protection against certain electric shock hazards. It does not eliminate all electric shock risks or replace proper earthing and safe electrical practices.

Why Choose VITS Pakistan?

VITS – Versatile Industrial Trading & Services supplies electrical, industrial and power distribution products for residential, commercial and industrial projects.

  • CHINT electrical products.
  • Industrial switchgear and circuit protection devices.
  • Electrical control and panel components.
  • Technical assistance for product selection.
  • Project and bulk quotation support.

819930RCCB, NXBLE-63, 819930, 2P, 6A, 30 / 300mA4500
819931RCCB, NXBLE-63, 819931, 2P, 10A, 30 / 300mA4500
819932RCCB, NXBLE-63, 819932, 2P, 16A, 30 / 300mA4500
819933RCCB, NXBLE-63, 819933, 2P, 20A, 30 / 300mA4500
819934RCCB, NXBLE-63, 819934, 2P, 25A, 30 / 300mA4500
819935RCCB, NXBLE-63, 819935, 2P, 32A, 30 / 300mA4500
819936RCCB, NXBLE-63, 819936, 2P, 40A, 30 / 300mA4500
819937RCCB, NXBLE-63, 819937, 2P, 50A, 30 / 300mA4800
819938RCCB, NXBLE-63, 819938, 2P, 63A, 30 / 300mA4800
982155RCBO, NXBLE-63, 982155, 4P, 6A, 30 / 300mA7500
982156RCBO, NXBLE-63, 982156, 4P, 10A, 30 / 300mA7500
982157RCBO, NXBLE-63, 982157, 4P, 16A, 30 / 300mA7500
982158RCBO, NXBLE-63, 982158, 4P, 20A, 30 / 300mA7500
982159RCBO, NXBLE-63, 982159, 4P, 25A, 30 / 300mA7500
982160RCBO, NXBLE-63, 982160, 4P, 32A, 30 / 300mA7500
982161RCBO, NXBLE-63, 982161, 4P, 40A, 30 / 300mA7500
982162RCBO, NXBLE-63, 982162, 4P, 50A, 30 / 300mA8000
982163RCBO, NXBLE-63, 982163, 4P, 63A, 30 / 300mA8000
982164RCBO, NXBLE-63, 982164, 4P, 100A, 30 / 300mA11000

VITS – Versatile Industrial Trading & Services

Engineering • Trading • Complete Industrial Solutions

Website: www.vits.com.pk

Phone / WhatsApp: 03134414901

Request a Quote: https://www.vits.com.pk/contact-us/


SEO SETTINGS

SEO Title: CHINT NXBLE-63 1P+N RCBO 6kA | VITS Pakistan

Focus Keyphrase: CHINT NXBLE-63 1P+N RCBO

Secondary Keywords:

  • CHINT NXBLE-63 RCBO
  • CHINT 1P+N RCBO
  • CHINT Residual Current Circuit Breaker
  • 1P+N Residual Current Breaker
  • 6kA RCBO
  • 30mA RCBO
  • 63A RCBO
  • Earth Leakage Circuit Breaker
  • Overload and Short Circuit Protection
  • CHINT RCBO Pakistan

URL Slug: chint-nxble-63-1p-n-rcbo

Meta Description: Buy CHINT NXBLE-63 1P+N RCBO with earth leakage, overload and short-circuit protection. Available in 6A–63A ratings. Contact VITS Pakistan for a quotation.

Product Category: Electrical Products → Circuit Breakers → RCBO

Product Brand: CHINT

Product Type: Variable Product (if selling multiple ratings and sensitivities); otherwise Simple Product.

SKU: Add confirmed VITS stock code.

Button Label: Request a Quote

Button URL: https://www.vits.com.pk/contact-us/

PRODUCT TAGS

CHINT, NXBLE-63, CHINT NXBLE-63, NXBLE-63 1P+N, 1P+N RCBO, RCBO, Residual Current Circuit Breaker, Residual Current Protection, Earth Leakage Protection, Earth Leakage Circuit Breaker, Overload Protection, Short Circuit Protection, 6kA RCBO, 30mA RCBO, 100mA RCBO, 300mA RCBO, B Curve RCBO, C Curve RCBO, D Curve RCBO, Single Phase RCBO, DIN Rail Circuit Breaker, CHINT Circuit Breaker, Electrical Protection Devices, VITS Pakistan

PRODUCT IMAGE SEO

Image File Name: chint-nxble-63-1p-n-rcbo-residual-current-circuit-breaker-vits-pakistan.webp

Alt Text: CHINT NXBLE-63 1P+N RCBO Residual Current Circuit Breaker

Image Title: CHINT NXBLE-63 1P+N RCBO

Image Caption: CHINT NXBLE-63 Single Phase Residual Current Circuit Breaker with Overload and Short Circuit Protection

Image Description: CHINT NXBLE-63 1P+N residual current circuit breaker with combined earth leakage, overload and short-circuit protection.

Image Dimensions: 1000 × 1000 px

Image Format: WebP

Image Background: White

Product Specifications

SpecificationDetails
BrandCHINT
ModelNXBLE-63
Product TypeResidual Current Circuit Breaker (RCBO)
Pole Configuration1P+N
Rated Current6A–63A
Rated Voltage230V AC
Frequency50/60Hz
Breaking Capacity6kA
Residual Current Sensitivity30mA, 50mA, 75mA, 100mA, 300mA
Tripping CurvesB, C, D
ProtectionEarth Leakage, Overload & Short Circuit
MountingDIN Rail
StandardIEC/EN 61009-1

Related Products

Reviews

There are no reviews yet.

Be the first to review “CHINT NXBLE-63 1P+N RCBO, 6A–63A, 6kA Residual Current Circuit Breaker | VITS Pakistan”