Chint NXB-63C MCB Breaker 1 pole 6ka

NL1-63 4P 30mA/300mA RCCB – Best Price & Reliable Protection

₨ 10,000

SKUDescription Ampere Ratings Sensitivity PriceQuantity
NL1-63-11

RCCB, NL1-63, 4P, 30ma

25 Amps 30mA ₨ 10,000
NL1-63-12

RCCB, NL1-63, 4P, 300ma

25 Amps 300mA ₨ 10,000
NL1-63-13

RCCB, NL1-63, 4P, 30ma

40 Amps 30mA ₨ 10,000
NL1-63-14

RCCB, NL1-63, 4P, 300ma

40 Amps 300mA ₨ 10,000
NL1-63-15

RCCB, NL1-63, 4P, 30ma

63 Amps 30mA ₨ 10,000
NL1-63-16

RCCB, NL1-63, 4P, 300ma

63 Amps 300mA ₨ 10,000
Brand:

Product Description

CHINT NL1-63 RCCB – 4P, 30mA / 300mA Residual Current Protection

Best Price | Reliable Protection | Premium Quality

1. Product Overview

The CHINT NL1-63 Residual Current Circuit Breaker (RCCB) is designed to detect earth-leakage currents and disconnect the electrical supply when residual current exceeds the specified operating threshold. It helps reduce the risk of electric shock and electrical fires caused by earth-leakage faults.

The four-pole configuration is suitable for compatible three-phase, four-wire electrical distribution systems. The NL1-63 range offers different rated-current and residual-current sensitivity options for residential, commercial, and industrial applications.

Available sensitivity options include 30mA and 300mA. These are separate product variants and must be selected according to the intended protection requirement.

Important: An RCCB provides residual-current protection only. It does not provide overload or short-circuit protection by itself and must be coordinated with suitable overcurrent protection.

2. Complete Technical Specifications

ParameterSpecification
BrandCHINT
Product seriesNL1-63
Product categoryResidual Current Circuit Breaker (RCCB)
Product typeResidual-current protection device without integrated overcurrent protection
Number of poles4P
Intended systemThree-phase, four-wire system
Rated current (In)Available variants include 25A, 40A and 63A; select the required rating
Rated residual operating current (IΔn)30mA or 300mA, depending on the selected variant
Rated operational voltage (Ue)400V AC for the four-pole version; regional documentation also lists 415V
Rated frequency50/60Hz
Residual-current detection typeType AC or Type A, depending on the exact product suffix
Overload protectionNot integrated
Short-circuit protectionNot integrated; suitable upstream/downstream protective coordination required
StandardIEC/EN 61008-1
Rated insulation voltage (Ui)500V for applicable 25A/40A/63A versions; confirm exact variant
Rated impulse withstand voltage (Uimp)4kV, as listed in product documentation
Rated residual making and breaking capacity (IΔm)500A for applicable ratings up to 40A; 630A for 63A versions
Rated conditional short-circuit currentDepends on the exact version and specified backup protective device; verify the applicable datasheet
Typical disconnection timeLess than 0.1 seconds for the normal, non-delayed version under specified test conditions
Protection degreeIP20, subject to correct installation
Mounting35mm DIN rail, according to EN 60715
ConnectionTop and bottom terminals
Terminal connectionCompatible cable or busbar, subject to terminal specifications
Ambient operating temperature−25°C to +40°C, subject to manufacturer’s conditions
Pollution degree2
Installation categoryClass II and III, as specified in the applicable manual
ApplicationEarth-leakage protection in low-voltage AC distribution systems

Specification note: These are range-level and model-family specifications based on CHINT documentation. Confirm the exact rated current, Type AC/Type A classification, short-circuit coordination, and product code before publishing a particular SKU or submitting it for project approval.

3. Available Sensitivity Options

30mA RCCB

The 30mA version is intended for applications requiring high-sensitivity residual-current protection, including supplementary protection against electric shock where required by the applicable electrical code.

Typical applications include:

  • Socket-outlet and final distribution circuits.
  • Residential and commercial electrical installations.
  • Circuits supplying equipment in areas where additional protection is required.
  • Suitable auxiliary and distribution circuits in industrial facilities.

300mA RCCB

The 300mA version is generally used where residual-current protection is required at a distribution or feeder level, including certain fire-risk protection strategies.

Typical applications include:

  • Main or sub-distribution panels.
  • Industrial feeder circuits.
  • Commercial building distribution systems.
  • Coordinated residual-current protection arrangements.

Selection advice: A 300mA RCCB is not a substitute for 30mA supplementary protection where the latter is required. For installations using both levels, check discrimination and selectivity between the devices. A time-delayed selective

In the intricate realm of electrical systems, safety isn’t just an option—it’s the number one priority. You might already know about basic circuit breakers, but let me introduce you to the NL1-63 4P 30mA/300mA, a true game-changer. This isn’t just another safety gadget; it’s a multifunctional, all-in-one solution crafted for professional use in tough environments. What sets this residual current circuit breaker apart is its dual-sensitivity protection, which lets you toggle between 30mA for personal safety and 300mA for serious fire prevention.

So, what does this mean for your electrical project? It translates to unmatched flexibility and control. Whether you’re protecting a commercial building, an industrial workshop, or a complex three-phase system, this single device delivers the right level of protection for any scenario. In this detailed guide, we’ll dive into the technology behind the NL1-63 4P 30mA/300mA, highlight its key features, and show you how to harness its capabilities for maximum security.

What is NL1-63 4P RCCB?

The NL1-63 is a four-pole Residual Current Circuit Breaker (RCCB) that’s specifically designed for low-voltage electrical distribution. Its job is straightforward yet crucial: it helps prevent electric shocks and fire hazards that can occur due to current leakage.

  • 4P (Four Pole): Perfect for three-phase systems that include a neutral line.
  • 30mA sensitivity: Protects people from dangerous electric shocks.
  • 300mA sensitivity: Prevents fire risks caused by higher leakage currents.
  • 63A rated current: Handles higher loads without compromise.

Key Features

  • High sensitivity protection against electric shocks.
  • Fire safety compliance with 300mA leakage detection.
  • Wide application in homes, offices, factories, and commercial sites.
  • Quick disconnection within milliseconds to ensure safety.
  • Durable build with long service life.
  • Compact design for easy installation in distribution boards.

Applications of NL1-63 4P RCCB

This RCCB is suitable for a wide range of environments:

Residential Buildings

  • Provides life-saving protection against electric shocks.
  • Ensures safe usage of household appliances.

Commercial Spaces

  • Ideal for shops, malls, and offices with multiple loads.
  • Protects sensitive electronics and employees.

Industrial Sites

  • Prevents fire risks in heavy load environments.
  • Suitable for machinery and three-phase equipment.

Why Choose NL1-63 4P, 30mA/300mA?

  • Dual sensitivity offers flexible usage in both residential and industrial setups.
  • Four-pole design makes it compatible with three-phase systems.
  • Enhanced safety ensures compliance with international standards.
  • Trusted performance reduces downtime and risk of electrical hazards.

Benefits at a Glance

  • Protects human life from electric shocks.
  • Prevents electrical fires caused by leakage currents.
  • Supports energy efficiency by preventing wastage.
  • Easy to install in standard distribution boards.
  • Environment-friendly with reduced risk of accidents.

You may also like:

NL1-63 2 Pole RCCB (30 mA & 300 mA) – Ultimate Safety Choice

Product Specifications

Compliant Standards: VITS61008-
1 Control electric circuits.
Protect people against indirect contacts and provide additional protection against direct contacts.
Protect installations against fire hazards due to insulation faults.

NL1 Residual Current Operated Circuit Breaker without Over-current Protection (Magnetic)

The NL1 Residual Current Circuit Breaker (RCCB) provides critical earth leakage protection, safeguarding people from indirect contacts and installations from fire hazards due to insulation faults. This essential device ensures reliable disconnection upon fault detection, enhancing safety across residential, commercial, and industrial electrical systems.

Note: This RCCB does not offer overcurrent protection and must be paired with an MCB or MCCB for complete circuit protection.

Compliant Standards and Certifications

 

  • IEC/EN 61008-1
  • IEC/EN 62423

 

Main Specifications

 

  • Type: AC, A, F
  • Rated Current (In): 16A, 25A, 32A, 40A, 63A, 80A, 100A
  • Poles: 2P, 4P
  • Rated Voltage (Ue): 230/400 to 240/415V, 110/127V (2P)
  • Rated Sensitivity (IΔn): 0.01A (25A 2P), 0.03A, 0.1A, 0.3A, 0.5A
  • Rated Residual Making and Breaking Capacity (IΔm): 500A (In ≤ 40A), 630A (In = 63A), 1,000A (In ≥ 80A)
  • Short-circuit Current (Inc): 10,000A with SCPD fuse
  • Break Time under IΔn: <0.1s (normal), 10 to 300ms (G/SI), 150 to 500ms (S type)
  • Rated Frequency: 50/60Hz
  • Rated Impulse Withstand Voltage (Uimp): 4,000V
  • Dielectric Test Voltage: 500V
  • Pollution Degree: 2

Related Products

Price range: ₨ 6,500 through ₨ 8,500
NXBLE-63-C63-1P-N-RCBO-2
Price range: ₨ 3,500 through ₨ 4,400

Reviews

There are no reviews yet.

Be the first to review “NL1-63 4P 30mA/300mA RCCB – Best Price & Reliable Protection”