Schneider Electric Acti9 iC60N – 2 Pole/Double Pole MCB, 10kA Breaking Capacity | VITS Pakistan

Price range: ₨ 7,500 through ₨ 22,000

SKU Ampere Ratings PriceQuantity
A9F44210 10 Amps ₨ 9,300
A9F44216 16 Amps ₨ 7,500
A9F44202 2 Amps ₨ 22,000
A9F44220 20 Amps ₨ 7,500
A9F44225 25 Amps ₨ 7,500
A9F44232 32 Amps ₨ 7,700
A9F44204 4 Amps ₨ 22,000
A9F44240 40 Amps ₨ 7,700
A9F44250 50 Amps ₨ 8,300
A9F44206 6 Amps ₨ 9,300
A9F44263 63 Amps ₨ 8,300
Brand:

Product Description

1. Detailed Product

Schneider Electric Acti9 iC60N – 2 Pole/Double Pole MCB, 10kA Breaking Capacity | VITS Pakistan

Product Overview

The Schneider Electric Acti9 iC60N 2 Pole Miniature Circuit Breaker (MCB) is designed to provide reliable protection for electrical circuits against overloads and short circuits.

Featuring thermal-magnetic tripping technology, this circuit breaker is suitable for commercial, industrial and residential electrical distribution systems.

With a rated ultimate short-circuit breaking capacity (Icu) of 10kA at 380–415V AC under IEC/EN 60947-2, the Acti9 iC60N is designed for installations requiring reliable circuit protection and operational safety.

Key Features & Benefits

  • Double Pole (2P) configuration.

  • 10kA ultimate breaking capacity (Icu) at 380–415V AC.

  • Thermal-magnetic protection technology.

  • Overload and short-circuit protection.

  • Available in multiple current ratings.

  • B, C and D tripping curves, depending on the selected variant.

  • Compact modular design.

  • DIN-rail mounting.

  • Compatible accessories available for selected product references.

  • Designed for commercial and industrial electrical distribution.

Technical Specifications

ParameterSpecification
BrandSchneider Electric
Product RangeActi9
Product SeriesiC60N
Product TypeMiniature Circuit Breaker (MCB)
Poles2 Pole (2P)
Protected Poles2
Rated CurrentVariant dependent
Tripping CurveB / C / D, variant dependent
Tripping TechnologyThermal-Magnetic
Rated Frequency50/60Hz
Rated Operational VoltageVariant dependent
Breaking Capacity (Icu)10kA at 380–415V AC
Icu at 220–240V AC20kA
Icu at 440V AC6kA
Icn at 400V AC6kA
Rated Insulation Voltage (Ui)500V AC
Impulse Withstand Voltage (Uimp)6kV
Utilisation CategoryCategory A
MountingDIN Rail
StandardsIEC/EN 60898-1, IEC/EN 60947-2

Note: Breaking-capacity values are dependent on the applicable standard and test voltage. Confirm the exact product reference and datasheet before final procurement or publication.

Protection Functions

1. Overload Protection

The thermal tripping mechanism protects electrical circuits against sustained overcurrent conditions that may cause cable and equipment overheating.

2. Short-Circuit Protection

The magnetic tripping mechanism provides rapid disconnection during short-circuit faults to help protect electrical installations.

3. Circuit Isolation

The Acti9 iC60N is designed for circuit isolation in accordance with applicable manufacturer instructions and standards.

Tripping Curve Selection

CurveMagnetic Tripping RangeTypical Application
B Curve3–5 × InLighting and resistive loads
C Curve5–10 × InGeneral commercial and industrial loads
D Curve10–20 × InHigh-inrush-current equipment

Select the tripping curve according to load characteristics and protection coordination requirements.

Applications

The Schneider Electric Acti9 iC60N 2 Pole MCB is suitable for:

  • Industrial electrical distribution panels.

  • Commercial building distribution boards.

  • Residential electrical installations.

  • Lighting distribution circuits.

  • HVAC and auxiliary equipment.

  • Control and automation panels.

  • General electrical power distribution.

  • Suitable AC/DC applications where explicitly permitted by the selected product’s ratings.

Accessories & Compatibility

Depending on the exact product reference, compatible accessories may include:

  • Auxiliary contact.

  • Alarm contact.

  • Shunt trip release.

  • Undervoltage release.

  • Residual-current protection module (Vigi).

  • Remote monitoring and control accessories.

Accessory compatibility must be checked against the exact MCB reference.

Installation Guidelines

  1. Select the rated current according to the connected load and cable capacity.

  2. Select the appropriate B, C or D tripping curve.

  3. Verify the prospective short-circuit current at the installation point.

  4. Confirm voltage and frequency compatibility.

  5. Ensure correct terminal connections.

  6. Install using a compatible DIN rail.

  7. Follow Schneider Electric installation instructions and specified terminal torque.

  8. Installation and testing must be performed by qualified electrical personnel.

Why Choose Schneider Electric Acti9 iC60N?

  • Reliable thermal-magnetic circuit protection.

  • Double-pole switching and protection configuration.

  • 10kA Icu at 380–415V AC under IEC/EN 60947-2.

  • Multiple current ratings and tripping curves.

  • Modular installation for electrical distribution boards.

  • Accessory options for selected product references.

  • Suitable for various commercial and industrial applications.

Frequently Asked Questions

Q1. What is Schneider Electric Acti9 iC60N?

It is a thermal-magnetic miniature circuit breaker designed to protect electrical circuits against overloads and short circuits.

Q2. What does 2 Pole mean?

It indicates a two-pole configuration, with both poles protected in the specified 2P version.

Q3. What does 10kA breaking capacity mean?

It represents the rated ultimate short-circuit breaking capacity (Icu) of 10kA at 380–415V AC under IEC/EN 60947-2.

Q4. Which current ratings are available?

The iC60N series is available in multiple current ratings. The exact rating depends on the selected product reference.

Q5. What is the difference between B, C and D curves?

They have different instantaneous magnetic tripping characteristics. B is generally used for lower-inrush loads, C for general-purpose loads and D for higher-inrush loads.

Q6. Can it be used in solar installations?

It may be suitable for specific AC or DC circuits only when the exact model’s voltage, current, polarity and breaking-capacity ratings meet the installation requirements. A dedicated PV DC breaker must be used where required by the system design.

Q7. Can auxiliary contacts be installed?

Selected iC60N references support compatible auxiliary accessories. Confirm compatibility before ordering.

Q8. Is it suitable for industrial electrical panels?

Yes. It can be used in suitable industrial distribution and control-panel applications when correctly selected and coordinated.

VITS Pakistan – Product Supply & Technical Support

VITS supplies electrical protection and distribution products for industrial, commercial and infrastructure projects across Pakistan.

We support customers with electrical product selection, technical specifications, distribution components and project-based supply requirements.

Contact VITS for pricing, availability and technical assistance for Schneider Electric Acti9 iC60N 2 Pole MCB.

VITS – Versatile Industrial Trading & Services

Engineering • Trading • Complete Industrial Solutions

Product Specifications

2. Short Description

Product Name: Schneider Electric Acti9 iC60N – 2 Pole/Double Pole MCB, 10kA Breaking Capacity | VITS Pakistan

AttributeDescription
BrandSchneider Electric
Product RangeActi9
Series / ModeliC60N
Product TypeMiniature Circuit Breaker (MCB)
Poles2 Pole (2P)
Rated CurrentVariant Dependent
Tripping CurveB / C / D (Variant Dependent)
Tripping TechnologyThermal-Magnetic
Breaking Capacity (Icu)10kA at 380–415V AC
Rated Frequency50/60Hz
Rated Insulation Voltage500V AC
Impulse Withstand Voltage6kV
ProtectionOverload & Short-Circuit
MountingDIN Rail
StandardsIEC/EN 60898-1, IEC/EN 60947-2
ApplicationsIndustrial, Commercial & Residential Electrical Distribution
SupplierVITS Pakistan

Note: Confirm rated current, tripping curve and exact part number before publishing the specific product variant.

VITS – Engineering • Trading • Complete Industrial Solutions

Related Products

Price range: ₨ 18,000 through ₨ 25,000
Acti9 C120N 1 Pole
Price range: ₨ 7,400 through ₨ 9,500
Acti 9 iC60H 1 Pole
Price range: ₨ 2,400 through ₨ 3,000
NXBLE-63-C63-1P-N-RCBO-2
Price range: ₨ 3,500 through ₨ 4,400

Reviews

There are no reviews yet.

Be the first to review “Schneider Electric Acti9 iC60N – 2 Pole/Double Pole MCB, 10kA Breaking Capacity | VITS Pakistan”

Your email address will not be published. Required fields are marked *