₨ 2,200
| SKU | Description | Ampere Ratings | Price | Quantity | |
|---|---|---|---|---|---|
| 813835 | MCB, NXB-63 H, 813835, 2P, 32A, Icu10kA, C-Curve | 32 Amps | ₨ 2,200 | ||
| 813836 | MCB, NXB-63 H, 813836, 2P, 40A, Icu10kA, C-Curve | 40 Amps | ₨ 2,200 | ||
| 813837 | MCB, NXB-63 H, 813837, 2P, 50A, Icu10kA, C-Curve | 50 Amps | ₨ 2,200 | ||
| 813838 | MCB, NXB-63 H, 813838, 2P, 63A, Icu10kA, C-Curve | 63 Amps | ₨ 2,200 |
The CHINT NXB-63H 2P Miniature Circuit Breaker (MCB) is designed to provide reliable protection against electrical overload and short-circuit faults in low-voltage electrical distribution systems. Featuring a rated short-circuit breaking capacity of 10kA, this double-pole circuit breaker is suitable for residential, commercial and industrial electrical installations.
Its thermal-magnetic tripping mechanism provides protection against excessive current and short-circuit conditions. The 2-pole configuration allows simultaneous switching and isolation of two conductors, making it suitable for compatible single-phase distribution applications.
With a compact modular design and standard DIN-rail mounting, the CHINT NXB-63H 2P MCB is an effective solution for distribution boards, electrical control panels and power distribution systems.
| Specification | Details |
|---|---|
| Brand | CHINT |
| Series | NXB-63H |
| Product Type | Miniature Circuit Breaker (MCB) |
| Pole Configuration | 2 Pole (Double Pole) |
| Breaking Capacity | 10kA |
| Rated Current | 1A–63A (Model Dependent) |
| Tripping Curve | B, C, D (Model Dependent) |
| Rated Voltage | According to selected 2P variant |
| Frequency | 50/60Hz |
| Protection | Overload & Short-Circuit |
| Tripping Mechanism | Thermal-Magnetic |
| Mounting | 35mm DIN Rail |
| Standard | IEC/EN 60898-1 |
| Parameter | Specification |
|---|---|
| Manufacturer | CHINT |
| Product Series | NXB-63H |
| Product Category | Miniature Circuit Breaker |
| Model Configuration | 2P |
| Number of Poles | 2 Poles |
| Rated Current (In) | 1A–63A |
| Rated Operational Voltage (Ue) | Confirm according to exact 2P model |
| Rated Frequency | 50/60Hz |
| Rated Short-Circuit Breaking Capacity (Icn) | 10kA |
| Rated Service Breaking Capacity (Ics) | Verify exact model datasheet |
| Tripping Characteristics | B, C, D |
| Rated Insulation Voltage (Ui) | Confirm manufacturer datasheet |
| Rated Impulse Withstand Voltage (Uimp) | Confirm manufacturer datasheet |
| Tripping Mechanism | Thermal-Magnetic |
| Applicable Standard | IEC/EN 60898-1 |
| Mounting Type | 35mm DIN Rail |
| Terminal Connection | As specified by manufacturer |
| Operating Temperature | Confirm exact model datasheet |
| Protection Degree | Refer to manufacturer datasheet |
Note: The NXB-63H is a product family. Electrical ratings and performance parameters must be verified against the exact 2P ordering code before publication.
10kA Breaking Capacity: Designed to interrupt short-circuit currents up to its rated breaking capacity under specified conditions.
Double Pole Configuration: Provides simultaneous switching of two poles.
Overload Protection: Thermal tripping mechanism protects circuits against sustained overcurrent.
Short-Circuit Protection: Magnetic tripping mechanism responds to high fault currents.
Thermal-Magnetic Technology: Combines overload and short-circuit protection in one device.
Multiple Tripping Curves: B, C and D curve options for different load characteristics.
Compact Modular Design: Suitable for modern electrical distribution boards.
DIN-Rail Mounting: Designed for compatible 35mm DIN-rail installation.
Reliable Circuit Isolation: Supports simultaneous disconnection of both poles.
Versatile Applications: Suitable for compatible residential, commercial and industrial installations.
The CHINT NXB-63H 2P MCB is suitable for:
Single-phase electrical distribution boards.
Residential power distribution systems.
Commercial building electrical panels.
Industrial control panels.
Lighting and power distribution circuits.
Electrical equipment protection circuits.
Workshop and factory electrical installations.
Auxiliary power supply circuits.
Compatible solar-system AC distribution circuits.
Electrical control and automation systems.
| Curve Type | Tripping Characteristics | Typical Applications |
|---|---|---|
| B Curve | Lower instantaneous magnetic trip threshold | Lighting and resistive loads |
| C Curve | Medium instantaneous magnetic trip threshold | General commercial and industrial loads |
| D Curve | Higher instantaneous magnetic trip threshold | Equipment with high starting or inrush current |
The appropriate tripping curve should be selected according to the connected load, starting current, cable capacity and protection coordination requirements.
The NXB-63H series includes different current ratings depending on the selected model.
| Rated Current | Example Model |
|---|---|
| 6A | NXB-63H 2P C6 10kA |
| 10A | NXB-63H 2P C10 10kA |
| 16A | NXB-63H 2P C16 10kA |
| 20A | NXB-63H 2P C20 10kA |
| 25A | NXB-63H 2P C25 10kA |
| 32A | NXB-63H 2P C32 10kA |
| 40A | NXB-63H 2P C40 10kA |
| 50A | NXB-63H 2P C50 10kA |
| 63A | NXB-63H 2P C63 10kA |
These are example model descriptions, not confirmed stock or ordering codes. Confirm availability and exact product references with CHINT.
Install the MCB on a compatible 35mm DIN rail.
Ensure the electrical supply is isolated before installation.
Verify the correct rated current, pole configuration and tripping curve.
Use conductors compatible with the manufacturer’s terminal specifications.
Tighten electrical connections according to the manufacturer’s recommended torque.
Ensure proper cable termination and insulation.
Check the electrical circuit and protection coordination before energising.
Confirm that the prospective short-circuit current does not exceed the MCB’s rated breaking capacity.
Installation and testing should be performed by a qualified electrician or electrical engineer.
| Protection Function | Description |
|---|---|
| Overload Protection | Protects electrical circuits against sustained excessive current. |
| Short-Circuit Protection | Interrupts high fault currents within the rated operating conditions. |
| Thermal Tripping | Responds to overload conditions through a thermal mechanism. |
| Magnetic Tripping | Provides rapid tripping during short-circuit conditions. |
| Double Pole Switching | Allows simultaneous switching of both poles. |
| Feature | 1P MCB | 2P MCB |
|---|---|---|
| Pole Configuration | Single Pole | Double Pole |
| Number of Poles | 1 | 2 |
| Switching | One pole | Two poles simultaneously |
| Module Width | Typically 1 module | Typically 2 modules |
| Application | Compatible single-phase circuit protection | Compatible two-conductor single-phase circuit protection |
| Isolation | One pole | Both poles |
VITS – Versatile Industrial Trading & Services provides electrical protection devices, industrial electrical equipment and power distribution solutions for commercial and industrial applications.
CHINT Global Version product sourcing.
CE-compliant product documentation for applicable supplied products.
Technical assistance for selecting appropriate MCB ratings.
Electrical protection and distribution equipment supply.
Switchgear and control panel solutions.
Support for industrial and commercial electrical requirements.
VITS Product Sourcing Policy: VITS deals in CHINT Global Version products and does not supply CCC-standard products sourced through grey channels in Pakistan. Product certification and compliance documentation should be verified against the actual supplied model and batch.
Q1. What is the CHINT NXB-63H 2P MCB used for?
It is used to protect compatible electrical circuits against overload and short-circuit faults.
Q2. What does 2P mean in an MCB?
2P means the circuit breaker has two poles that operate together for simultaneous switching and isolation.
Q3. What does 10kA breaking capacity mean?
It represents the rated short-circuit current that the MCB is designed to interrupt under specified test conditions.
Q4. What current ratings are available?
The NXB-63H series includes different current ratings from 1A to 63A, depending on the selected model.
Q5. What is the difference between B, C and D curves?
B, C and D curves have different instantaneous magnetic tripping characteristics and are selected according to the load’s starting current.
Q6. Can the NXB-63H 2P MCB be used in distribution boards?
Yes. It is designed for compatible DIN-rail installation in electrical distribution boards and control panels.
Q7. Does the 2P MCB provide overload and short-circuit protection?
Yes. Its thermal-magnetic mechanism provides both overload and short-circuit protection.
Q8. Is this MCB suitable for industrial applications?
Yes. It can be used in suitable industrial distribution and control circuits when correctly selected for the electrical installation.
Q9. Does an MCB provide earth-leakage protection?
No. An MCB does not provide earth-leakage protection. An appropriate RCCB, RCD or RCBO is required where earth-leakage protection is specified.
Q10. What is the difference between NXB-63 and NXB-63H?
The NXB-63H series has a different short-circuit breaking capacity specification from the standard NXB-63 series. Always verify the exact product model and manufacturer datasheet.
| SEO Field | Recommended Content |
|---|---|
| SEO Title | CHINT NXB-63H 2P/Double Pole Miniature Circuit Breaker (MCB) 10kA | VITS Pakistan |
| Focus Keyphrase | CHINT NXB-63H 2P MCB 10kA |
| Secondary Keywords | CHINT 2 Pole MCB, CHINT Double Pole Circuit Breaker, CHINT 10kA MCB, NXB-63H 2P MCB, CHINT MCB Pakistan |
| URL Slug | chint-nxb-63h-2p-double-pole-mcb-10ka |
| Meta Description | Buy CHINT NXB-63H 2P Double Pole MCB 10kA from VITS Pakistan. Reliable overload and short-circuit protection for residential, commercial and industrial electrical systems. |
| Product Category | Electrical Protection Devices |
| Subcategory | Miniature Circuit Breakers (MCB) |
| Brand | CHINT |
| Product Type | Variable Product (if multiple current ratings are offered) |
| Image Field | Recommended Content |
|---|---|
| Image Filename | CHINT_NXB-63H_2P_10kA_MCB_VITS_Pakistan.png |
| Image Alt Text | CHINT NXB-63H 2P Double Pole Miniature Circuit Breaker 10kA |
| Image Title | CHINT NXB-63H 2P MCB 10kA |
| Image Size | 1000 × 1000 px |
| Image Background | Pure White |
| Image Format | PNG or WebP |
Recommended Product Images:
Front view of CHINT NXB-63H 2P MCB.
Three-quarter product view.
Side view showing technical markings.
Terminal connection view.
Product dimensions and mounting details.
| Field | Content |
|---|---|
| Button Title / Label | Request a Quote |
| Button Link / URL | https://www.vits.com.pk/contact-us/ |
| Alternative Button | Get Latest Price |
VITS – Versatile Industrial Trading & Services
Engineering • Trading • Complete Industrial Solutions
Website: www.vits.com.pk
Contact: 03134414901
| Specification | Details |
|---|---|
| Brand | CHINT |
| Model | NXB-63H |
| Product Type | Miniature Circuit Breaker (MCB) |
| Pole Configuration | 2 Pole (Double Pole) |
| Breaking Capacity | 10kA |
| Rated Current | 1A–63A (Model Dependent) |
| Tripping Curve | B, C, D (Model Dependent) |
| Rated Voltage | As per selected model |
| Frequency | 50/60Hz |
| Protection | Overload & Short-Circuit |
| Tripping Mechanism | Thermal-Magnetic |
| Mounting | 35mm DIN Rail |
| Standard | IEC/EN 60898-1 |
| Model no. | Description |
| 813835 | MCB, NXB-63 H, 2 Pole, C-Curve |
| 813836 | MCB, NXB-63 H, 2 Pole, C-Curve |
| 813837 | MCB, NXB-63 H, 2 Pole, C-Curve |
| 813838 | MCB, NXB-63 H, 2 Pole, C-Curve |


Reviews
There are no reviews yet.