₨ 1,250
| SKU | Description | Ampere Ratings | Price | Quantity | |
|---|---|---|---|---|---|
| 813792 | MCB, NXB-63 H, 1 Pole, C-Curve | 10 Amps | ₨ 1,250 | ||
| 813793 | MCB, NXB-63 H, 1 Pole, C-Curve | 16 Amps | ₨ 1,250 | ||
| 813794 | MCB, NXB-63 H, 1 Pole, C-Curve | 20 Amps | ₨ 1,250 | ||
| 813796 | MCB, NXB-63 H, 1 Pole, C-Curve | 32 Amps | ₨ 1,250 | ||
| 813797 | MCB, NXB-63 H, 1 Pole, C-Curve | 40 Amps | ₨ 1,250 | ||
| 813799 | MCB, NXB-63 H, 1 Pole, C-Curve | 63 Amps | ₨ 1,250 |
The CHINT NXB-63H 1P Miniature Circuit Breaker (MCB) is a compact thermal-magnetic protective device designed to protect single-phase electrical circuits against overload and short-circuit faults. With a rated short-circuit breaking capacity of 10kA, it is suitable for low-voltage residential, commercial and industrial distribution applications where a higher fault-interruption capacity is required.
The NXB-63H series offers B, C and D tripping characteristics and current ratings from 1A to 63A, allowing selection according to the connected load and circuit protection requirements. Its modular DIN-rail design makes it suitable for distribution boards, control panels and electrical enclosures.
CHINT global+1
| Specification | Details |
|---|---|
| Brand | CHINT |
| Product Series | NXB-63H |
| Product Type | Miniature Circuit Breaker (MCB) |
| Number of Poles | 1 Pole (1P) |
| Breaking Capacity | 10kA |
| Rated Current | 1A–63A (model dependent) |
| Tripping Curve | B, C, D (model dependent) |
| Rated Voltage | 220/230/240V AC |
| Frequency | 50/60Hz |
| Protection | Overload and short-circuit |
| Mounting | 35mm DIN rail |
| Standard | IEC/EN 60898-1 |
CHINT global+1
| Parameter | Technical details |
|---|---|
| Manufacturer | CHINT |
| Series | NXB-63H |
| Device category | MCB |
| Pole configuration | 1P |
| Rated operational voltage (Ue) | 220/230/240V AC |
| Rated current (In) | 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A |
| Tripping characteristics | B, C, D |
| Rated short-circuit breaking capacity | 10kA |
| Short-circuit service capacity (Ics) | 7.5kA |
| Rated insulation voltage (Ui) | 500V |
| Rated impulse withstand voltage (Uimp) | 4kV |
| Rated frequency | 50/60Hz |
| Release mechanism | Thermal-magnetic |
| Applicable standard | IEC/EN 60898-1 |
| Mechanical endurance | Up to 20,000 operations |
| Electrical endurance | Up to 10,000 operations |
| Operating temperature | -35°C to +70°C |
| Storage temperature | -35°C to +85°C |
| Mounting | 35mm DIN rail (TH35-7.5) |
| Terminal capacity | 1–25mm² solid; 1–16mm² flexible |
| Connection torque | 2N·m |
| Wire insertion depth | 11mm |
| Protection degree | IP20 direct mounting; IP40 in a suitable distribution enclosure |
| Maximum applicable altitude | 2,000m |
| Pollution degree | Class II |
These are series-level manufacturer specifications. Confirm the exact model’s rating and installation limits against its current CHINT datasheet before publishing a selected variant.
CHINT global+1
10kA breaking capacity: Designed to interrupt short-circuit currents up to the stated rated breaking capacity under specified test conditions.
Overload protection: Thermal tripping mechanism helps protect conductors and connected equipment from sustained overcurrent.
Short-circuit protection: Magnetic tripping mechanism responds rapidly to high fault currents.
Multiple trip curves: B, C and D options support different load characteristics.
Compact 1P configuration: Occupies one modular pole position in a compatible distribution board.
DIN-rail installation: Designed for standard 35mm DIN-rail mounting.
Positive isolation: Provides circuit isolation in accordance with the manufacturer’s product design and applicable installation requirements.
Accessory compatibility: Supports selected auxiliary and trip accessories in the NXB-63H accessory family.
CHINT global+1
| Curve | Typical application | General selection guidance |
|---|---|---|
| B Curve | Lighting and predominantly resistive loads | Loads with relatively low starting current |
| C Curve | General commercial and industrial circuits | Loads with moderate inrush current |
| D Curve | Certain motors, transformers and equipment with high starting current | Loads with higher inrush current, subject to engineering assessment |
The trip curve must be selected according to the actual load, conductor size, prospective short-circuit current and disconnection requirements. Do not select a D-curve breaker simply because the connected equipment is a motor.
The CHINT NXB-63H 1P MCB can be used in:
Residential distribution boards.
Commercial building electrical panels.
Industrial control panels.
Lighting and power distribution circuits.
Single-phase equipment protection circuits.
Control and automation panels.
Electrical distribution boards in workshops and factories.
Auxiliary and control supply circuits.
Compatible solar-system auxiliary AC circuits.
Important: The MCB must be selected for the actual circuit voltage, current, cable capacity, fault level and protection coordination. It is not a substitute for an RCD/RCCB or earth-leakage protection device.
Install on a compatible 35mm DIN rail inside an appropriate electrical enclosure.
Isolate the upstream supply before installation or maintenance.
Verify the correct rated current, pole configuration and tripping curve.
Use conductors within the manufacturer’s specified terminal capacity.
Tighten terminals to the specified torque for the selected product.
Check conductor insulation and ensure no exposed copper remains outside the terminal.
Verify circuit polarity, continuity and protective-device coordination before energising.
Installation and testing must be performed by a qualified electrical professional.
The NXB-63H 1P range is offered in different rated currents and trip characteristics. Examples include:
| Rated current | Example C-curve designation |
|---|---|
| 6A | NXB-63H 1P C6 10kA |
| 10A | NXB-63H 1P C10 10kA |
| 16A | NXB-63H 1P C16 10kA |
| 20A | NXB-63H 1P C20 10kA |
| 25A | NXB-63H 1P C25 10kA |
| 32A | NXB-63H 1P C32 10kA |
| 40A | NXB-63H 1P C40 10kA |
| 50A | NXB-63H 1P C50 10kA |
| 63A | NXB-63H 1P C63 10kA |
Other ratings and B/D curves are also available in the series. Confirm availability and the exact CHINT ordering code before placing an order.
Chint Global+1
VITS provides electrical protection and distribution products for residential, commercial and industrial applications.
CHINT Global Version product sourcing.
CE-compliant product documentation for the applicable supplied version.
Technical assistance with MCB selection and ratings.
Support for electrical panel and distribution-board requirements.
Supply support for industrial electrical equipment and switchgear solutions.
VITS product sourcing policy: VITS deals in CHINT Global Version products and does not offer CCC-standard products sourced through grey channels in Pakistan. Product certification and compliance documents should be verified against the supplied model and batch.
Q1. What is the CHINT NXB-63H 1P MCB used for?
It is used to protect single-phase electrical circuits against overload and short-circuit faults.
Q2. What does 10kA breaking capacity mean?
It indicates the rated short-circuit breaking capacity of the breaker under specified test conditions. The prospective fault current at the installation point must not exceed the applicable rating.
Q3. What current ratings are available?
The NXB-63H series includes rated currents from 1A to 63A, depending on the selected configuration.
Q4. What is the difference between B, C and D curves?
They have different instantaneous magnetic tripping characteristics and are selected according to the load’s starting current and protection requirements.
Q5. Can this MCB be installed in a distribution board?
Yes. It is designed for compatible 35mm DIN-rail mounting in a suitable distribution enclosure.
Q6. Does the NXB-63H provide overload and short-circuit protection?
Yes. It uses thermal-magnetic protection for overload and short-circuit conditions.
Q7. Is it suitable for industrial applications?
Yes, it can be used in suitable industrial distribution and control circuits when its current rating, breaking capacity and trip curve match the installation requirements.
Q8. Does it provide earth-leakage protection?
No. An MCB does not provide earth-leakage protection. An appropriate RCCB, RCD or RCBO is required where earth-leakage protection is specified.
Q9. What is the difference between NXB-63 and NXB-63H?
The NXB-63H series has a 10kA rated short-circuit breaking capacity, while the standard NXB-63 series has different breaking-capacity specifications. Always check the exact model marking and datasheet.
CHINT global+2
| SEO field | Recommended content |
|---|---|
| Product SEO Title | CHINT NXB-63H 1P/Single Pole Miniature Circuit Breaker (MCB) 10kA | VITS Pakistan |
| Focus Keyphrase | CHINT NXB-63H 1P MCB 10kA |
| Secondary Keywords | CHINT 1 Pole MCB, CHINT 10kA MCB, NXB-63H Circuit Breaker, CHINT Miniature Circuit Breaker |
| URL Slug | chint-nxb-63h-1p-single-pole-mcb-10ka |
| Meta Description | Buy CHINT NXB-63H 1P Single Pole MCB 10kA from VITS Pakistan. Reliable overload and short-circuit protection with B, C and D curve options. |
| Product Category | Electrical Protection Devices |
| Subcategory | Miniature Circuit Breakers (MCB) |
| Brand | CHINT |
| Product Condition | New |
| Product Type | Variable product (if offering multiple current ratings and curves) |
Recommended main image filename
CHINT_NXB-63H_1P_10kA_MCB_VITS_Pakistan.png
Alt text: CHINT NXB-63H 1P Single Pole Miniature Circuit Breaker 10kA
Image title: CHINT NXB-63H 1P MCB 10kA
Illustrative product reference. Use the actual CHINT product photograph for accurate markings and appearance.
Recommended additional website images:
Front view of the 1P breaker.
Side view with dimensions.
Terminal connection view.
DIN-rail mounting view.
Product range showing different current ratings.
Official manufacturer product page: CHINT NXB-63H – Official Product Page.
Manufacturer catalogue: CHINT NXB-63H Technical Catalogue
| Specification | Details |
|---|---|
| Brand | CHINT |
| Model | NXB-63H |
| Product Type | Miniature Circuit Breaker (MCB) |
| Pole Configuration | 1 Pole (Single Pole) |
| Breaking Capacity | 10kA |
| Rated Current | 1A–63A (Model Dependent) |
| Tripping Curve | B, C, D (Model Dependent) |
| Rated Voltage | 220/230/240V AC |
| Protection | Overload & Short-Circuit |
| Mounting | 35mm DIN Rail |
| Standard | IEC/EN 60898-1 |
| Model no. | Description |
| 813792 | MCB, NXB-63 H, 1 Pole, C-Curve |
| 813793 | MCB, NXB-63 H, 1 Pole, C-Curve |
| 813794 | MCB, NXB-63 H, 1 Pole, C-Curve |
| 813796 | MCB, NXB-63 H, 1 Pole, C-Curve |
| 813797 | MCB, NXB-63 H, 1 Pole, C-Curve |
| 813799 | MCB, NXB-63 H, 1 Pole, C-Curve |

Reviews