Chint NXB-63C MCB Breaker 1 pole 6ka

CHINT NXBLE-63 4 Pole RCBO, 6A–63A, 400V AC, 6kA | VITS Pakistan

Price range: ₨ 6,000 through ₨ 10,000

SKUDescription Ampere Ratings Sensitivity PriceQuantity
982183

RCBO, NXBLE-63, 4P, 30mA

6 Amps 30mA ₨ 6,000
982184

RCBO, NXBLE-63, 4P, 300mA

6 Amps 300mA ₨ 6,200
982185

RCBO, NXBLE-63, 4P, 30mA

10 Amps 30mA ₨ 6,000
982186

RCBO, NXBLE-63, 4P, 300mA

10 Amps 300mA ₨ 6,200
982187

RCBO, NXBLE-63, 4P, 30mA

16 Amps 30mA ₨ 6,000
982188

RCBO, NXBLE-63, 4P, 300mA

16 Amps 300mA ₨ 6,200
982189

RCBO, NXBLE-63, 4P, 30mA

20 Amps 30mA ₨ 6,000
982190

RCBO, NXBLE-63, 4P, 300mA

20 Amps 300mA ₨ 6,200
982191

RCBO, NXBLE-63, 4P, 30mA

25 Amps 30mA ₨ 6,000
982192

RCBO, NXBLE-63, 4P, 300mA

25 Amps 300mA ₨ 6,200
982193

RCBO, NXBLE-63, 4P, 30mA

32 Amps 30mA ₨ 6,000
982194

RCBO, NXBLE-63, 4P, 300mA

32 Amps 300mA ₨ 6,200
982195

RCBO, NXBLE-63, 4P, 30mA

40 Amps 30mA ₨ 6,000
982196

RCBO, NXBLE-63, 4P, 300mA

40 Amps 300mA ₨ 6,200
982197

RCBO, NXBLE-63, 4P, 30mA

50 Amps 30mA ₨ 6,000
982198

RCBO, NXBLE-63, 4P, 300mA

50 Amps 300mA ₨ 6,200
982199

RCBO, NXBLE-63, 4P, 30mA

63 Amps 30mA ₨ 6,200
982200

RCBO, NXBLE-63, 4P, 300mA

63 Amps 300mA ₨ 6,200
982201

RCBO, NXBLE-63, 4P, 30mA

100 Amps 30mA ₨ 10,000
982202

RCBO, NXBLE-63, 4P, 300mA

100 Amps 300mA ₨ 10,000
Brand:

Product Description

Product Description

The CHINT NXBLE-63 4-Pole Residual Current Circuit Breaker (RCBO) is designed to provide combined earth leakage, overload and short-circuit protection in three-phase electrical installations.

Combining residual current protection with thermal-magnetic overcurrent protection in one compact device, the NXBLE-63 helps protect electrical circuits, equipment and installations against electrical faults.

With a four-pole configuration, this RCBO is designed for suitable three-phase applications requiring switching and protection across four conductors. Its rated operating voltage is 400V AC, with current ratings ranging from 6A to 63A.

The NXBLE-63 is suitable for commercial buildings, industrial distribution boards, electrical control panels and three-phase power distribution systems.

Short Description

SpecificationDetails
BrandCHINT
SeriesNXBLE-63
Product TypeResidual Current Circuit Breaker (RCBO)
Pole Configuration4 Pole (4P)
Rated Current6A–63A
Rated Voltage400V AC
Frequency50/60Hz
Breaking Capacity (Icu)6kA
Service Breaking Capacity (Ics)6kA
Residual Current Sensitivity30mA, 50mA, 75mA, 100mA, 300mA
Tripping CharacteristicsB, C, D
ProtectionEarth Leakage, Overload & Short Circuit
MountingDIN Rail
StandardIEC/EN 61009-1

Technical Specifications

Technical ParameterSpecification
ManufacturerCHINT
Product ModelNXBLE-63
Number of Poles4P
Rated Current (In)6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Rated Voltage (Ue)400V AC
Rated Frequency50/60Hz
Rated Residual Operating Current (IΔn)30mA, 50mA, 75mA, 100mA, 300mA
Tripping CharacteristicsB, C, D
Rated Short-Circuit Breaking Capacity (Icu)6kA
Service Short-Circuit Breaking Capacity (Ics)6kA
Rated Impulse Withstand Voltage (Uimp)4kV
Mechanical Life20,000 operations
Electrical Life10,000 operations
Applicable StandardIEC/EN 61009-1
MountingDIN Rail

Key Features

  • Combined residual current and overcurrent protection.
  • Four-pole configuration for suitable three-phase installations.
  • 400V AC rated voltage.
  • Current ratings from 6A to 63A.
  • 6kA short-circuit breaking capacity.
  • Multiple residual current sensitivity options.
  • B, C and D tripping characteristics.
  • Compact modular construction.
  • DIN rail mounting.
  • Designed in accordance with IEC/EN 61009-1.

Protection Functions

1. Earth Leakage Protection

Detects residual current caused by earth leakage and disconnects the circuit when the applicable operating threshold is reached.

2. Overload Protection

Provides thermal protection against excessive current flowing through the electrical circuit over time.

3. Short-Circuit Protection

Provides magnetic protection against short-circuit faults to help limit damage to electrical installations and equipment.

Available Current Ratings

Rated CurrentConfiguration
6A4P RCBO
10A4P RCBO
16A4P RCBO
20A4P RCBO
25A4P RCBO
32A4P RCBO
40A4P RCBO
50A4P RCBO
63A4P RCBO

Individual ratings and combinations are subject to product availability.

Tripping Characteristics

CurveGeneral Application
B CurveResistive and low-inrush-current loads
C CurveGeneral commercial and industrial loads
D CurveLoads with high starting or inrush current

Select the appropriate tripping characteristic according to the connected load, cable capacity and prospective fault current.

Applications

  • Three-phase electrical distribution boards.
  • Commercial buildings.
  • Industrial electrical panels.
  • Three-phase machinery and equipment.
  • Commercial power distribution systems.
  • Industrial control panels.
  • Three-phase circuits requiring residual current protection.
  • Electrical installations requiring combined earth leakage and overcurrent protection.

Installation and Safety

  • Installation must be performed by a qualified electrician.
  • Confirm the rated current and voltage before installation.
  • Select the appropriate residual current sensitivity.
  • Verify the correct B, C or D tripping characteristic.
  • Follow the manufacturer’s terminal connection diagram.
  • Confirm the neutral and phase conductor arrangement.
  • Ensure proper protective earthing.
  • Test the device according to the manufacturer’s instructions.
  • Isolate all electrical supplies before installation or maintenance.

Important: An RCBO does not replace the protective earthing system. Correct earthing, wiring and circuit coordination are essential for safe operation.

Frequently Asked Questions

Q1. What is CHINT NXBLE-63 4P RCBO?

It is a four-pole residual current circuit breaker with integrated overload and short-circuit protection.

Q2. What is the rated voltage of the 4-pole model?

CHINT specifies 400V AC for the 4-pole version in its product catalogue.

Q3. What protection does this RCBO provide?

It combines earth leakage, overload and short-circuit protection.

Q4. What current ratings are available?

The series includes 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A and 63A.

Q5. What is its breaking capacity?

The manufacturer specifies 6kA rated short-circuit breaking capacity.

Q6. Can it be used in three-phase distribution panels?

Yes. The 4-pole configuration is designed for suitable three-phase AC electrical installations.

Q7. What is the difference between an MCB and an RCBO?

An MCB provides overload and short-circuit protection, while an RCBO combines these functions with residual current protection.

Q8. Does this product provide earth leakage protection?

Yes. It detects residual current and disconnects the circuit when the applicable operating threshold is reached.

Why Choose VITS Pakistan?

VITS – Versatile Industrial Trading & Services supplies electrical, industrial and power distribution products for commercial and industrial projects.

  • Industrial electrical equipment and switchgear supply.
  • Circuit protection and distribution products.
  • CHINT product sourcing.
  • Technical assistance for product selection.
  • Project and bulk quotation support.
819930RCCB, NXBLE-63, 819930, 2P, 6A, 30 / 300mA4500
819931RCCB, NXBLE-63, 819931, 2P, 10A, 30 / 300mA4500
819932RCCB, NXBLE-63, 819932, 2P, 16A, 30 / 300mA4500
819933RCCB, NXBLE-63, 819933, 2P, 20A, 30 / 300mA4500
819934RCCB, NXBLE-63, 819934, 2P, 25A, 30 / 300mA4500
819935RCCB, NXBLE-63, 819935, 2P, 32A, 30 / 300mA4500
819936RCCB, NXBLE-63, 819936, 2P, 40A, 30 / 300mA4500
819937RCCB, NXBLE-63, 819937, 2P, 50A, 30 / 300mA4800
819938RCCB, NXBLE-63, 819938, 2P, 63A, 30 / 300mA4800
982155RCBO, NXBLE-63, 982155, 4P, 6A, 30 / 300mA7500
982156RCBO, NXBLE-63, 982156, 4P, 10A, 30 / 300mA7500
982157RCBO, NXBLE-63, 982157, 4P, 16A, 30 / 300mA7500
982158RCBO, NXBLE-63, 982158, 4P, 20A, 30 / 300mA7500
982159RCBO, NXBLE-63, 982159, 4P, 25A, 30 / 300mA7500
982160RCBO, NXBLE-63, 982160, 4P, 32A, 30 / 300mA7500
982161RCBO, NXBLE-63, 982161, 4P, 40A, 30 / 300mA7500
982162RCBO, NXBLE-63, 982162, 4P, 50A, 30 / 300mA8000
982163RCBO, NXBLE-63, 982163, 4P, 63A, 30 / 300mA8000
982164RCBO, NXBLE-63, 982164, 4P, 100A, 30 / 300mA11000

VITS – Versatile Industrial Trading & Services

Engineering • Trading • Complete Industrial Solutions

Website: www.vits.com.pk

Phone / WhatsApp: 03134414901

Request a Quote: https://www.vits.com.pk/contact-us/

Product Specifications

SpecificationDetails
BrandCHINT
ModelNXBLE-63
Product TypeResidual Current Circuit Breaker (RCBO)
Pole Configuration4 Pole (4P)
Rated Current6A–63A
Rated Voltage400V AC
Frequency50/60Hz
Breaking Capacity6kA
Residual Current Sensitivity30mA, 50mA, 75mA, 100mA, 300mA
Tripping CurvesB, C, D
ProtectionEarth Leakage, Overload & Short Circuit
MountingDIN Rail
StandardIEC/EN 61009-1

Related Products

Price range: ₨ 18,000 through ₨ 36,000

Reviews

There are no reviews yet.

Be the first to review “CHINT NXBLE-63 4 Pole RCBO, 6A–63A, 400V AC, 6kA | VITS Pakistan”

Your email address will not be published. Required fields are marked *