Chint NXB-63C MCB Breaker 1 pole 6ka

CHINT NB1-63DC 4P/Four Pole DC Circuit Breaker, 1000V DC, 6kA | VITS Pakistan

₨ 8,000

SKUDescription Ampere Ratings PriceQuantity
182728

MCB, NB1-63DC, 4P, 1000 VDC

1 Amps ₨ 8,000
182729

MCB, NB1-63DC, 4P, 1000 VDC

2 Amps ₨ 8,000
182730

MCB, NB1-63DC, 4P, 1000 VDC

3 Amps ₨ 8,000
182731

MCB, NB1-63DC, 4P, 1000 VDC

4 Amps ₨ 8,000
182732

MCB, NB1-63DC, 4P, 1000 VDC

6 Amps ₨ 8,000
182733

MCB, NB1-63DC, 4P, 1000 VDC

10 Amps ₨ 8,000
182734

MCB, NB1-63DC, 4P, 1000 VDC

16 Amps ₨ 8,000
182735

MCB, NB1-63DC, 4P, 1000 VDC

20 Amps ₨ 8,000
182736

MCB, NB1-63DC, 4P, 1000 VDC

25 Amps ₨ 8,000
182737

MCB, NB1-63DC, 4P, 1000 VDC

32 Amps ₨ 8,000
182738

MCB, NB1-63DC, 4P, 1000 VDC

40 Amps ₨ 8,000
182739

MCB, NB1-63DC, 4P, 1000 VDC

50 Amps ₨ 8,000
182740

MCB, NB1-63DC, 4P, 1000 VDC

63 Amps ₨ 8,000
Brand:

Product Description

CHINT NB1-63DC 4P DC Circuit Breaker – 1000V DC, 6kA

  • The CHINT NB1-63DC 4 Pole DC Circuit Breaker is designed to provide overload and short-circuit protection in high-voltage DC electrical systems. With a rated operating voltage of 1000V DC, rated current options from 1A to 63A, and a rated short-circuit breaking capacity of 6kA, it is suitable for photovoltaic installations, DC distribution systems, energy storage applications and other compatible DC circuits.
  • Its four-pole configuration is designed for 1000V DC applications. The breaker features C-curve tripping characteristics, DIN-rail mounting, dual connection capability for conductors and busbars, and a compact modular design for electrical distribution and control panels.
  • CHINT NB1-63DC is manufactured in accordance with IEC/EN 60947-2 and RoHS requirements. VITS focuses on supplying CHINT Global Version products with applicable CE compliance documentation, subject to verification of the supplied model and batch.
Key Features
  1. Four-pole DC circuit breaker configuration
  2. Rated operating voltage: 1000V DC
  3. Rated current range: 1A–63A
  4. Rated short-circuit breaking capacity: 6kA
  5. C-curve tripping characteristic (7–10 × In)
  6. Overload and short-circuit protection
  7. DIN-rail installation
  8. Dual connection capability for lead wires and busbars
  9. Compact modular construction
  10. ON/OFF contact position indication
  11. Designed for compatible solar PV and DC distribution applications
Applications
  • Solar photovoltaic DC distribution systems
  • Solar PV combiner and distribution panels, where the design and voltage rating are compatible
  • DC power distribution systems
  • Battery energy storage systems, where the breaker is suitable for the battery fault-current characteristics
  • Industrial DC control and power circuits
  • Telecommunications DC power networks
  • Other engineered DC applications within the manufacturer’s ratings
Protection Functions
  • Overload protection: Helps protect connected conductors and equipment against sustained overcurrent conditions.
  • Short-circuit protection: Provides interruption of DC short-circuit current within the breaker’s specified voltage and breaking-capacity limits.
  • Important: Correct selection requires checking the system voltage, prospective fault current, conductor size, polarity and manufacturer’s DC wiring arrangement.
  • Why Choose VITS?
VITS – Versatile Industrial Trading & Services provides electrical equipment, industrial solutions and technical support for commercial and industrial applications.
  • CHINT Global Version product sourcing
  • Focus on applicable CE-compliant product documentation
  • Support for product selection and technical enquiries
  • Supply solutions for solar and industrial electrical projects
VITS – Engineering • Trading • Complete Industrial Solutions
Website: www.vits.com.pk
Contact: 03134414901

Product Specifications

Short description

Use this table in the WooCommerce Product Short Description field.
Specification
Details
Brand
CHINT
Series
NB1-63DC
Product Type
DC Circuit Breaker / DC MCB
Number of Poles
4P
Rated Voltage
1000V DC
Rated Current
1A–63A
Breaking Capacity (Icu)
6kA
Tripping Curve
C Curve
Magnetic Tripping Range
7–10 × In
Standard
IEC/EN 60947-2
Impulse Withstand Voltage
4kV
Protection Degree
IP20
Mounting
DIN Rail
Mechanical Life
20,000 operations
Electrical Life
1,500 operations
Operating Temperature
−35°C to +70°C
Brand Origin
CHINT
Availability
Subject to stock confirmation
CHINT global+2
4. Detailed technical specifications
Parameter
Manufacturer information
Product Series
NB1-63DC
Pole Configuration
4 Pole
Rated Operational Voltage (Ue)
1000V DC
Rated Current (In)
1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63A
Rated Ultimate Breaking Capacity (Icu)
6kA
Tripping Characteristic
C Type
Magnetic Tripping Range
7–10 × In
Standard
IEC/EN 60947-2
Rated Impulse Withstand Voltage (Uimp)
4kV
Mechanical Life
20,000 operations
Electrical Life
1,500 operations
Protection Degree
IP20
Ambient Temperature
−35°C to +70°C
Maximum Installation Altitude
2,000m; derating may apply above this
Conductor Capacity
Up to 25mm²
Tightening Torque
2N·m
Connection
Lead wire and busbar compatible
Mounting
DIN rail
Weight
Approximately 0.12kg per pole
CHINT global+2
5. Available current ratings
A.2 NB1 Series P-246+1
6. Installation and selection notes

Confirm the DC system’s maximum operating voltage does not exceed the 4P breaker’s 1000V DC rating.

Check the prospective short-circuit current against the 6kA breaking capacity.

Follow the manufacturer’s specified terminal and polarity/wiring arrangement for DC operation.

Select the current rating according to cable ampacity, load current and applicable protection coordination.

Use suitable DC-rated cables, terminals and busbars.

Tighten terminals to the specified 2N·m torque, subject to the product’s current instructions.

Installation must be performed by a qualified electrical professional with the DC circuit safely isolated.

Important: Do not assume that any four-pole AC breaker can replace a DC breaker. DC arc interruption and connection arrangements are different. Follow the CHINT wiring diagram for the exact product.
7. Frequently asked questions
Q1. What is the voltage rating of CHINT NB1-63DC 4P?
The 4-pole version is rated at 1000V DC.
Q2. What is the maximum current rating?
The available rated current range is 1A to 63A.
Q3. What is its breaking capacity?
The rated ultimate short-circuit breaking capacity (Icu) is 6kA.
Q4. Is it suitable for solar applications?
Yes. It can be used in compatible solar PV DC circuits when the system voltage, fault current, wiring arrangement and protection design are within the manufacturer’s ratings.
Q5. What tripping curve does it use?
It uses a C-type tripping characteristic, with a magnetic tripping range of 7–10 times rated current.
Q6. Can it be installed on a DIN rail?
Yes. It is designed for DIN-rail mounting.
Q7. Is it suitable for battery protection?
It may be suitable for specific DC battery circuits, but battery fault current and system configuration must be assessed before selection.
Q8. Is it a CHINT Global Version product?
VITS focuses on CHINT Global Version products. Confirm the model marking and applicable compliance documents for the actual supplied batch before purchase.
8. Technical documents
Official manufacturer resources:

CHINT NB1-63DC Official Product Page

CHINT NB1-63DC Product Catalogue (PDF)

CHINT NB1-63DC Installation Manual (PDF)

9. SEO settings for WordPress / Rank Math / Yoast
SEO Field
Recommended Content
SEO Title
CHINT NB1-63DC 4 Pole DC MCB 1000V 6kA | VITS Pakistan
Focus Keyphrase
CHINT NB1-63DC 4 Pole DC Circuit Breaker
Secondary Keywords
CHINT 1000V DC MCB, 4 Pole DC Circuit Breaker, CHINT DC MCB 6kA, Solar DC Circuit Breaker
URL Slug
chint-nb1-63dc-4-pole-dc-circuit-breaker
Meta Description
Buy CHINT NB1-63DC 4 Pole DC Circuit Breaker, 1000V DC and 6kA, with current ratings from 1A to 63A. Contact VITS Pakistan for pricing and availability.
Product Category
Circuit Breakers → DC Circuit Breakers
Product Brand
CHINT
Product Type
Simple Product, or Variable Product if listing multiple current ratings
Canonical URL: Use the actual published WooCommerce product URL. If the slug above is used, verify the final permalink after publishing.
10. Product image SEO
Field
Recommended Content
Image Filename
chint-nb1-63dc-4-pole-1000v-dc-circuit-breaker-vits-pakistan.webp
Image Alt Text
CHINT NB1-63DC 4 Pole 1000V DC 6kA Circuit Breaker
Image Title
CHINT NB1-63DC 4P DC Circuit Breaker
Image Caption
CHINT NB1-63DC 4P DC Circuit Breaker – 1000V DC
Image Description
CHINT NB1-63DC four-pole DC circuit breaker for compatible 1000V DC electrical applications. Available through VITS Pakistan.
Image Size
1000 × 1000 px
Format
WebP
Background
White
11. Product tags
CHINT, CHINT NB1-63DC, NB1-63DC 4P, CHINT DC MCB, 4 Pole DC Circuit Breaker, Four Pole DC MCB, 1000V DC Circuit Breaker, 6kA DC MCB, Solar DC Circuit Breaker, DC Protection, DC MCB 63A, Photovoltaic Protection, Solar PV Protection, DC Distribution, Battery Storage Protection, Industrial DC Circuit Breaker, CHINT Global Version, VITS Pakistan.
12. Product enquiry button
Button label: Request a Quote
Button URL: https://www.vits.com.pk/contact-us/
Contact: 03134414901
13. Important publishing checks
Before publishing this product page:

Confirm the exact 4P model and current rating on the actual product label.

Confirm the supplied product’s Global Version identity and applicable CE documentation. CHINT’s family-level information lists several certification schemes; VITS’s CE-focused supply policy should be supported by documents for the actual batch.

Do not advertise a fixed price until VITS confirms the current selling price.

If you list all current ratings, use a variable product with a separate variation for each rating, where stock and pricing are available.

Use the manufacturer’s wiring diagram for the 4P DC connection arrangement. Do not invent terminal polarity or connection instructions.

158104
MCB, GDZ158-125, 158104, 2P, 125A, Icu6kA, 500 VDC
                   7,000
182714
MCB, NB1-63DC, 182714, 2P, 1A, 500 VDC
                   4,800
182715
MCB, NB1-63DC, 182715, 2P, 2A, 500 VDC
                   4,800
182716
MCB, NB1-63DC, 182716, 2P, 3A, 500 VDC
                   4,800
182717
MCB, NB1-63DC, 182717, 2P, 4A, 500 VDC
                   4,800
182718
MCB, NB1-63DC, 182718, 2P, 6A, 500 VDC
                   4,800
182719
MCB, NB1-63DC, 182719, 2P, 10A, 500 VDC
                   4,800
182720
MCB, NB1-63DC, 182720, 2P, 16A, 500 VDC
                   4,800
182721
MCB, NB1-63DC, 182721, 2P, 20A, 500 VDC
                   4,800
182722
MCB, NB1-63DC, 182722, 2P, 25A, 500 VDC
                   4,800
182723
MCB, NB1-63DC, 182723, 2P, 32A, 500 VDC
                   4,800
182724
MCB, NB1-63DC, 182724, 2P, 40A, 500 VDC
                   4,800
182725
MCB, NB1-63DC, 182725, 2P, 50A, 500 VDC
                   4,800
182726
MCB, NB1-63DC, 182726, 2P, 63A, 500 VDC
                   4,800
182727
MCB, NB1-63DC, 182727, 4P, 1A, 1000 VDC
                   9,000
182728
MCB, NB1-63DC, 182728, 4P, 2A, 1000 VDC
                   9,000
182729
MCB, NB1-63DC, 182729, 4P, 3A, 1000 VDC
                   9,000
182730
MCB, NB1-63DC, 182730, 4P, 4A, 1000 VDC
                   9,000
182731
MCB, NB1-63DC, 182731, 4P, 6A, 1000 VDC
                   9,000
182732
MCB, NB1-63DC, 182732, 4P, 10A, 1000 VDC
                   9,000
182734
MCB, NB1-63DC, 182734, 4P, 16A, 1000 VDC
                   9,000
182735
MCB, NB1-63DC, 182735, 4P, 20A, 1000 VDC
                   9,000
182736
MCB, NB1-63DC, 182736, 4P, 25A, 1000 VDC
                   9,000
182737
MCB, NB1-63DC, 182737, 4P, 32A, 1000 VDC
                   9,000
182738
MCB, NB1-63DC, 182738, 4P, 40A, 1000 VDC
                   9,000
182739
MCB, NB1-63DC, 182739, 4P, 50A, 1000 VDC
                   9,000
182740
MCB, NB1-63DC, 182740, 4P, 63A, 1000 VDC
                   9,000

Related Products

CHINT Miniature Circuit Breaker (MCB) 6kA (NXB-63C) MCB Breaker
Price range: ₨ 770 through ₨ 4,400

Reviews

There are no reviews yet.

Be the first to review “CHINT NB1-63DC 4P/Four Pole DC Circuit Breaker, 1000V DC, 6kA | VITS Pakistan”

Your email address will not be published. Required fields are marked *